Smoke screens

Smoke screens are a part of the smoke and heat extraction system. Produced in compliance with EN12101-1. Smoke barriers limit the spread of toxic gases released in a fire.

Smoke screens are very important, since we determine that:

  • 90% of all victims die from smoke
  • 70% of all material damage is caused by smoke
  • The seat of the fire and the causes of the fire can not be detected directly by the fire brigade by the smoke

Moducoil

The smoke screen “Moducoil” consists of several curtains that overlap.

Advantages :

  • Endless lengths
  • Elements of 3-4-5-6m
  • Height up to 7m
  • Fast delivery
  • Easy placement

Moducoil smoke screens comply with the EN 12101-1 standard.

Supercoil

The Supercoil is distinguished by its flexibility and possibilities for customisation. The smoke curtain can be produced in one piece up to a width of 50 metres and a height of 9.5 metres. It is designed for high time ratings at temperature loads of 600 °C (D) and 1100 °C (ETK curve – DH).

When using guide rails over the entire height, leakage is limited. The smoke curtain closes by gravity by means of a ‘Fail Safe’ motor, therefore an external power supply is not needed and fire resistant cabling is unnecessary. The Supercoil has small built-in dimensions, closes to the ground and can be provided with an opening to create an escape route. The Supercoil can also be produced in combination with the walk-through smoke screen Stripecoil, which makes escape even easier.

The Supercoil smoke curtains comply with the EN 12101-1 standard.

Stripecoil

The walk-through smoke curtain that closes to the floor. The Stripecoil is the smoke curtain for passages in escape routes and designed for temperature classes up to D120 (heat resistance for more than 120 minutes at a test temperature of max. 600°C) and DH30 (heat resistance for more than 30 minutes at a test temperature according to the unit temperature curve. From a width of 3 metres, approx. 200 persons (also with prams and wheelchairs) per minute can pass through the passageway.

A soft and flexible sealing edge of the individual fabric strips helps to minimise the risk of injury. The smoke curtain closes by gravity using a ‘Fail Safe’ motor, therefore an external power supply is not required and fire resistant cabling is not needed.

The Stripecoil smoke curtains comply with the EN 12101-1 standard.

Smokeshield S

Rectangular or polygonal smoke curtain with a maximum length per side of 16 metres and roll-up length up to 6 metres. Suitable for high time classes and temperature loads D120 (600 °C). Neither ceiling nor corner columns are required and yet an absolute seal is created despite the high pressure load. The casing has a low build-in height of approx. 125 mm with a roll-up length of < 3.0 metres. The smoke curtain closes by gravity using a ‘Fail Safe’ motor, therefore an external power supply is not required and fire resistant cabling is not needed.

The Smokeshield-S smoke curtains comply with the EN 12101-1 standard.

Smokeshield C

The curved smoke screen with 0% leakage. It is available up to 300 metres and 4 metres in length. It can withstand temperatures up to 600°C. Standard drive system “Gravigen” that closes without additional energy, i.e. fireproof cables are not required.

Stöbich